• Home
  • Current congress
  • Public Website
  • My papers
  • root
  • browse
  • IAC-12
  • A2
  • 5
  • paper
  • Bias determination for the MICROSCOPE accelerometers using the ZARM Catapult system - experimental setup and data analysis

    Paper number

    IAC-12,A2,5,4,x14878

    Author

    Mr. Hanns Selig, ZARM - University of Bremen, Germany

    Coauthor

    Prof. Claus Laemmerzahl, ZARM - University of Bremen, Germany

    Year

    2012

    Abstract
    Accelerometers for space applications - like the electrostatic differential accelerometer for the MICROSCOPE mission for testing the equivalence principle in space - have to be tested and qualified in $\mu$µg-conditions in order to demonstrate the system operation and to determine the characteristic sensor parameters. One important characteristic property is the sensor bias. In principle one can determine the sensor bias directly by using the 110 m catapult system at ZARM as test platform. Even in the evacuated drop tube the residual air pressure results in an air friction that depends on the capsule velocity. At the apex (highest point of the capsule trajectory) the acceleration (relative to the gravitational acceleration g) becomes zero due to the zero velocity at the apex. The direct measurement of the vertical linear acceleration sensor bias is affected by some additional effects that have to be understood in order to be able to determine the sensor bias. Two catapult campaigns have been carried out to demonstrate the principles of the bias determination using a SuperStar accelerometer (Onera). The presentation gives an overview on the experimental setup and on the corresponding data analysis.
    Abstract document

    IAC-12,A2,5,4,x14878.brief.pdf

    Manuscript document

    IAC-12,A2,5,4,x14878.pdf (🔒 authorized access only).

    To get the manuscript, please contact IAF Secretariat.