• Home
  • Current congress
  • Public Website
  • My papers
  • root
  • browse
  • IAC-22
  • A3
  • IPB
  • paper
  • Development of a space dosimetry payload for the Mars Sample Return Earth Return Orbiter

    Paper number

    IAC-22,A3,IPB,38,x73707

    Author

    Mr. Balazs Zabori, Hungary, MTA Centre for Energy Research

    Coauthor

    Dr. Attila Hirn, Hungary

    Coauthor

    Ms. Boglarka Erdos, Hungary, MTA Centre for Energy Research

    Coauthor

    Mr. Gergely Gutay, Hungary

    Coauthor

    Mr. Janos Szoke, Hungary, Admatis Ltd.

    Year

    2022

    Abstract
    Space radiation poses one of the most important risks during long-term crewed missions, especially those going beyond low Earth orbit. The radiation environment in space is highly variable and very complex; there is no single dosimeter or one single method to determine the dose to the astronauts in this radiation field. Instead, a wide variety of dosimeter types (sensitive to different components and particle energies) and modelling (radiation transport calculations) are needed to estimate the dose to the members of the crew. Earth Return Orbiter (ERO) of the Mars Sample Return (MSR) program, being the first spacecraft planned to travel from Earth to Mars and back
    again, represents a unique opportunity to characterize the return-trip radiation environment in order to inform future missions. Space radiation measurements conducted in the past in
    the interplanetary space between Earth and Mars, and in Mars orbit either focused only on determining dosimetry quantities or providing space weather data products (particle spectra
    measurements); no direct simultaneous measurements have been performed so far on the same spacecraft. The Centre for Energy Research Space Research Department (EK-UKL) providedthe technical feasibility, high-level requirements, and development roadmap of a Space Dosimetry Telescope (SDT) for implementation on MSR-ERO. The primary objectives of the SDT are:
    \begin{itemize}\item to determine the time series of dosimetric quantities (LET spectra, absorbed dose rate, dose equivalent rate, mean quality factor of the charged particle component of the space radiation) for the Earth-Mars cruise, the Mars orbit and Mars-Earth return mission segments of the MSR-ERO mission behind different typical shielding thicknesses expected for astronauts, in order to support radiation health risk assessment and mitigation for
    future human space missions; and\end{itemize}
    \begin{itemize}\item to determine the time series of the charged particle flux and energy spectra of space radiation for the Earth-Mars cruise, the Mars orbit and Mars-Earth return mission segments of the MSR-ERO mission, in order to support radiation environment modelling of future human space missions.\end{itemize}
    The data products of charged particle flux and energy spectra of space radiation will enable deeper assessment of dosimetric data products to be estimated based on energy deposition measurements. Present paper gives an overview of the system level concept of the payload and the preliminary design, the targeted data products to be measured, and the results of
    calculations on the expected measurement performance.
    Abstract document

    IAC-22,A3,IPB,38,x73707.brief.pdf

    Manuscript document